Selection of a Clarification Mode
There may be several possible alternatives for a given application.  Selection of a filter or separator for a particular application generally involves compromise.

Your Goals for a Coolant System should be prioritized to aid in your selection.

In addition, capabilities may also narrow the field (e.g., a magnetic separator would be a poor choice for an aluminum machining operation).

Application-appropriate selections are given in the table below.

COOLANT CLARIFICATION MODE RECOMMENDATIONS FOR SPECIFIC APPLICATIONS

STEEL, POWDERED METAL
CAST IRON, NODULAR IRON
ALUMINUM
GENERAL MACHINING -
e.g., mill, drill, broach, turn
A  D  F
G  H  I
A  D  F
G  H  I
A  D
G  H  I
FINISH MACHINING -
e.g., gun drill, ream, bore
B  D  F
G  H  I
B  D  F
G  I
B  D
G  H  I
GRINDING -
rough to medium
B  H  I
B  I
B  I
FINISH GRIND &
POLISH
C  E  I
E  I
CONSULT
ENGRG.
SUPERFINISHING -
e.g., honing, microsizing
C  E  I
E  I
CONSULT
ENGRG.

A - Gravity Permanent Media in Primary Conveyor Tank
B - Gravity Disposable Media with Flat Bottom Clean Tank
C - Gravity Disposable Media with Magnetic Separator
D - Bag Filter Fed from Primary Conveyor Tank
E - Magnetic Separator Fed from Machine Base
F - Magnetic Separator Fed from Primary Conveyor Tank
G - Centrifugal Separator Fed from Primary Conveyor Tank
H - Vacuum Permanent Media Filter
 I - Vacuum Disposable Media Filter